Effect of Phase Change Material Melting Points on Thermal Protection Behavior of Firefighters’ Turnout Gear

1 National Institute for Occupational Safety and Health, National Personal Protective Technology Laboratory, Pittsburgh, PA 15236, USA ↗
2 National Institute for Occupational Safety and Health, National Personal Protective, Technology Laboratory, Pittsburgh, PA 15236, USA ↗
3 Northeastern State University, Department of Physical Sciences, Tahlequah, OK 74464, USA ↗
Publication year
Digital Object Identifier10.54941/ahfe1006270

Abstract

Between 2018 and 2022, an average of 21,955 fireground injuries occurred annually in the United States [1]. Among these, thermal burns were one of the most common injuries, accounting for approximately 10% of fireground incidents [1]. This underscores the urgent need to improve turnout gear technology to provide better thermal protection for firefighters. Phase change materials (PCMs) can absorb substantial amounts of latent heat during the melting process while maintaining a constant temperature, which makes them ideal for enhancing thermal protection. Our proposal aims to leverage this protective property integrating PCM segments into turnout gear to improve its thermal protective performance (TPP). This study involves numerical simulations, which will serve as a foundation for future experimental designs and testing protocols. While existing numerical studies on fire protective clothing typically utilize one-dimensional (1D) models [2], there is a lack of comprehensive three-dimensional (3D) models that are capable of assessing the overall thermal performance of turnout gear on the human body. The goal is to determine the optimal PCM melting temperature range for turnout gear, maximizing thermal protection for firefighters. MethodWe conducted 3D heat transfer simulations using COMSOL Multiphysics (COMSOL, Inc., Burlington, MA 01803, USA). To accommodate firefighters' movements and activities in fire scenes, PCM was broken into multiple segments covering the main body while avoiding joints. The bioheat transfer module was utilized to model the human body's thermal regulation. The equivalent heat capacity method was employed to simulate the phase change process. Adhering to the guidelines of the National Fire Protection Association (NFPA 1971, Standard on Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting), heat fluxes of 83 kW/m2 and 8.3 kW/m2 were applied to the outer surface of turnout gear to replicate flashover and hazardous conditions, respectively [3,4]. These heat fluxes represented the radiant/convective heat sources in fire scenes. The 3.0-mm-thick PCM segments were utilized based on the prior research by our team [5]. We investigated the effects of different melting points of PCMs at various locations in clothing fabrics on the thermal protection behavior of PCM-integrated turnout gear. PCM melting points in the range of 40°C-200°C were evaluated. Three PCM locations-1 mm, 2 mm, and 3 mm beneath the outer shell surface-were investigated to explore the effect of PCM location on the optimum melting temperaturesResultsResults show that a PCM melting temperature range of 50°C-70°C provides optimal protection for the human body, extending the time it takes to reach second-degree burns from 18 seconds to approximately 45 seconds. This range is particularly effective because it aligns with the threshold for second-degree burns (approximately 60°C), helping to maintain skin temperature at or below 60°C for extended periods during fire exposure, thereby reducing the risk of severe burn injuries. Additionally, positioning the PCM closer to the inner surface of the clothing enhances its thermal protective performance.ConclusionIncorporating PCM segments with melting point of 50°C-70°C into firefighter turnout gear could increase the time it takes for skin to reach the threshold for second-degree burns by around 1.5 to 3 times, compared to traditional gear without PCM technology. The insights gained from 3D modeling provide a valuable foundation for developing next-generation turnout gear for firefighters.DisclaimerThe findings and conclusions in this abstract are those of the authors and do not necessarily represent the official position of the National Institute for Occupational Safety and Health (NIOSH), Centers for Disease Control and Prevention (CDC). Mention of any company or product does not constitute endorsement by NIOSH, CDC.References[1] Campbell, R. Firefighter Injuries on the Fireground. NFPA Research, July 2024. Available from: https://www.nfpa.org/education-and-research/research/nfpa-research/fire-statistical-reports/patterns-of-firefighter-fireground-injuries[2] Fonseca, A., Neves, S.F., Campos, J.B.L.M., 2021. Thermal performance of a PCM firefighting suit considering transient periods of fire exposure, post-fire exposure and resting phases. Applied Thermal Engineering 182, 115769.[3] NFPA 1971, Standard on Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting, 2018.[4] Coletta, G.C., Arons, I.J., Ashley, L.E., Drennan, A.P.,1976. The Development of Criteria for Firefighters' Gloves Volume II: Glove Criteria and Test Methods. Contract No. CDC-99-74-59, February 1976.

INTRODUCTION

Between 2018 and 2022, an average of 21,955 firefighter injuries occurred on the fireground annually in the United States, with thermal burns accounting for approximately 10% of these incidents (National Fire Protection Association, 2023). Firefighting remains one of the most dangerous occupations, and the risks firefighters face from thermal exposure highlight the urgent need for enhanced protective technologies. Turnout gear, the primary defense against fire hazards, plays a crucial role in safeguarding firefighters from thermal stress. The current firefighters’ turnout gear thermal protective performance (TPP) rating must be no less than 35.0, equating to 17.5 seconds before second-degree burns occur in a flashover situation based on NFPA 1971 (Standard on Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting). However, it can take much longer time than a

© 2025. Published by AHFE Open Access. All rights reserved. 59

few seconds for firefighters to conduct rescue tasks in fire scenes. Hence, it is critical to enhance the thermal protection function of firefighter clothing for longer time protection under extreme heat conditions. One promising solution is the integration of phase change materials (PCMs) into firefighter turnout gear (Brundrett and Harmer, 2021).

PCMs are materials that can absorb substantial amounts of latent heat during their phase transition from solid to liquid, all while maintaining a constant temperature (Mondal, 2008). This unique thermal property makes PCMs an ideal candidate for improving the thermal protection of firefighter turnout gear. The integration of PCMs allows for the absorption of excess heat, providing a buffer that helps maintain safer body temperatures (below second-degree burn temperature, ∼60

  • C (Coletta et al., 1976)) for the firefighter. When PCM melts, it absorbs heat from the environment, reducing the amount of heat transferred to the firefighter’s skin. Once the PCM solidifies, it releases the stored heat, helping to regulate the temperature within the gear. This ability to stabilize temperature during extreme thermal events could significantly reduce the risk of thermal burns and improve overall safety for firefighters exposed to high-heat environments (Balaji et al., 2020). The effectiveness of PCMs is dependent on their melting points, as different PCMs have different thermal properties. It is crucial to identify the optimal melting point for PCM integration into turnout gear to achieve the best thermal protection for firefighters. The ideal PCM should melt at a temperature that maximizes its protective capabilities. As such, understanding the relationship between the PCM’s melting point and the heat exposure firefighters experience is essential for developing turnout gear that offers optimal thermal protection.

This study aims to explore and optimize the use of PCMs in firefighter turnout gear by determining the most effective PCM melting temperature range for turnout gear application. Numerical simulations will be employed to model the behavior of PCMs under fireground conditions, providing valuable insights into how different melting points affect the overall TPP of the gear. The TPP represents the time for the skin surface to reach second- degree burn under high heat exposures. The longer time the gear can hold skin below second-degree burn indicates better thermal protection. These simulations will serve as a foundation for the development of experimental designs and testing protocols, ultimately guiding the creation of more effective protective gear.

While existing numerical studies on fire protective clothing typically use one-dimensional (1D) models to assess heat transfer and protective capabilities (Fonseca et al., 2018; Fonseca et al., 2021; Hu et al., 2013; McCarthy and di Marzo, 2012; Zhang et al., 2021), there is a significant gap in the literature when it comes to the use of three-dimensional (3D) models for evaluating the full thermal performance of turnout gear. One-dimensional models often fail to account for the complex interactions between the gear and the human body in dynamic, real-world firefighting scenarios. In contrast, 3D models offer a more comprehensive approach by simulating heat transfer across the entire body and gear system, including the thermal effects

Effect of Phase Change Material Melting Points on Thermal Protection Behavior 61

on different body parts and how the gear performs during actual firefighting activities. These models are essential for accurately predicting the thermal protection provided by turnout gear and assessing the effectiveness of PCM integration.

Hence, this research will contribute to the development of more advanced 3D modeling techniques for evaluating fire protective clothing, which could improve the design and testing of future firefighter gear. The primary objective of this research is to identify the optimum melting temperature range and the corresponding location of PCM in firefighters’ turnout gear to maximize thermal protection.

Ultimately, the findings from this study could lay the groundwork for the development of turnout gear with enhanced thermal protection. By optimizing PCM, this research has the potential to improve firefighter safety, reduce burn injuries, and provide more effective protective solutions for firefighters exposed to extreme heat on the fireground.

METHODS

A 3D human thermal body model was built in COMSOL Multiphysics (COMSOL, Inc., Burlington, MA 01803, USA). The Bioheat Transfer module in COMSOL was used for the heat transfer simulations.

3D Turnout Gear-Equipped Human Thermal Model The human body model was built based on the anthropometric data of firefighters’ bodies collected by NIOSH as explained in a previous publication by Xu and colleagues (2024). The firefighters’ turnout gear model was built outside the human body. The overall thickness of the clothing was 6 mm (including the outer shell, moisture barrier, and thermal barrier), measured based on commercial firefighters’ protective clothing (Globe GX-7 Firefighter JACKET Coat Size 36/32 Turnout Gear). Bio-based PCM (fatty acids) was used and embedded in the clothing material for thermal protection due to its nontoxic and thermally and chemically stable nature (PureTemp LLC). The PCM was broken into several segments to cover the body thermal zones – calf, thigh, abdomen, chest, back, and arms (ASTM F1291–16), but to avoid blocking joints to maintain firefighters’ activities, as shown in Figure 1. The sizes of PCM segments were in the range of 4"–6.5", depending on the location they covered. The segments covering the limb areas were 4" × 11", while the segments covering the abdomen, chest, and back areas were 4.5" × 6" or 4.5" × 6.5" (Figure 1).

Based on the previous study, we found that 3-mm-thick PCM segments could achieve good thermal protection because it has sufficient thickness to provide enough thermal protection while not adding significant weight to firefighters’ turnout gear (Xu et al., 2024). Hence, the 3-mm-thick PCM segments were applied to this study. Three different locations of PCM segments in turnout gear were explored, including 1-mm, 2-mm, and 3-mm below the outer surface of turnout gear, as shown in Figure 2. The PCM segment could replace part of the thermal barrier Hence, the overall thickness of the turnout gear clothing would not be increased. PCM melting points,

using various PCMs in the range of 40–200

  • C, were investigated to explore the optimum melting temperature range for turnout gear application.
Figure 1: The 3D turnout gear-equipped human thermal model with PCM segments embedded in clothing. Probes 1–3 are at the locations directly protected by PCM segments.
Original PDF Figure 1:
Figure 2: Locations of PCM segments in firefighters’ turnout gear, located at 1-mm, 2-mm, and 3-mm (from right to left) below the outer surface of turnout gear. The PCM thickness is 3-mm (constant).
Original PDF Figure 2:

Three-dimensional (3D) heat transfer simulations were conducted for the firefighters’ turnout gear-equipped human body. The transient heat diffusion equation was applied as the governing equation to simulate the thermal transport phenomena in turnout gear and PCM segments (Su et al., 2020; Xu et al., 2022). A bioheat source term was added to the heat diffusion equation for the human body to account for the effect of blood circulation on body heat transfer (Su et al., 2020; Xu et al., 2022). The equivalent heat capacity method was used to simulate the phase changing process of PCM segments (Xu et al., 2022; Xu et al., 2024). The thermophysical properties of human skin, firefighters’ turnout gear, and PCM input into the model for numerical simulations are listed in Table 1.

Effect of Phase Change Material Melting Points on Thermal Protection Behavior 63

Table 1: Thermophysical properties of human skin, firefighters’ turnout gear, and PCM (ASTM F1930–18; Harris et al., 1982; Incropera and DeWitt, 2002; PureTemp LLC; Ventura and Martelli, 2009; Xu et al., 2022; Xu et al., 2024).

Table available in the original PDF paper.

Layer of Protection

Density (kg/m3)

Specific Heat (kJ/kg·K)

Latent Heat of Fusion (kJ/kg)

Thermal Conductivity (W/m·K)

Human skin 0.36 1109 2.68 ----- Firefighters’

0.30 500.0 1.30

turnout gear PCM 0.20 (avg.) 814.5 2.00 213.0

Boundary conditions: The turnout gear-equipped firefighter model was exposed to radiant/convective heat sources, mimicking the fire scenes. The heat fluxes of 83 kW/m2 and 8.3 kW/m2 were applied at the outer surface of the turnout gear in the simulation model as external heat sources, representing the flashover and hazardous conditions in the fire scene, respectively (Coletta et al., 1976).

Initial conditions: The initial temperature of firefighters’ turnout gear was assumed to be 25

  • C (typical room temperature). The initial human body temperature was maintained around 37
  • C (the normal human core temperature). Governing equations can be found in our previous work (Xu et al., 2022; Xu et al., 2024).

Mesh for Modelling and Numerical Solution Reading Points The finite element method was adopted for the numerical simulations. Free tetrahedral elements were used to establish the mesh structure for the 3D model (Xu et al., 2024). The mesh independent study indicated that the finer mesh size in COMSOL was sufficient for the human thermal model. Four (4) representative probes were built on the skin surface of the human model to record the skin surface temperature data during the heat exposures, as shown in Figure 1. Probe 0 is at the location where there is no PCM segment directly covering (protecting). It is used as the baseline for the comparison study. Probes 1–3 are at the locations directly protected by PCM segments. Probe 1 is located at the chest (human trunk area). Probes 2 and 3 are located at the arm and leg, respectively (the human limbs area).

HEAT TRANSFER ANALYSIS RESULTS

Figure 3 shows the times for skin surfaces at various locations (on the human trunk and limbs) to reach second-degree burn temperature (around 60

  • C (Coletta et al., 1976)) when they were covered (protected) by different melting points of PCMs. Figures 3(c) and (d) give the correlations to predict the PCM thermal protection performances with respect to the melting points on the human body. The optimum melting temperature was observed in the range of 40–90
  • C under flashover condition and 50–80
  • C under hazardous condition.

In addition, the effect of PCM location in turnout gear on the temperature control performance was investigated. Figure 4 displays temperature profiles

on the human body skin surfaces under flashover condition (heat flux of 83 kW/m2). PCM melting point of 60

  • C was selected in this study based on the optimum melting temperature range. It shows the temperatures on the chest (Probe 1) and arm (Probe 2) to represent the cases on the human trunk and limb, respectively.

DISCUSSION

This study investigated how the PCM melting points in firefighters’ turnout gear affected the overall thermal protection capability. The PCM segment could enhance the thermal protection capability by 1–2 times when compared to the area not directly covered by PCM (Probe 0). The PCM melting points in the range of 40–90

  • C and 50–80
  • C provided the best thermal protection performance for the flashover and hazardous condition, respectively, as shown in Figure 3(a) and (b). Overall, the PCM melting temperature falling in the 50–80
  • C interval could provide the best thermal protection for the firefighters’ turnout gear application, and it showed similar optimum melting temperature intervals at different locations on the human body (Probes 1–3: chest, arm, leg). When the PCM melting point was too high (such as above 90
  • C), it could not melt efficiently under heat exposures, losing the phase change function and, therefore, the thermal protection capability. Hence, the protection time decreased when the PCM melting point exceeded 90
  • C. When the melting points were lower (around the skin’s second-degree burn temperature), it showed better protection performance due to the effective phase change function and, therefore, the capability of maintaining skin temperature below the second-degree burn point. Under the flashover condition, the thermal protection time, defined as the duration for the skin surface temperature to reach 60
  • C, remained within 45–55 seconds when the PCM had melting points between 40
  • C and 90
  • C. However, this duration decreased when the melting point exceeded 90
  • C. Under hazardous conditions, the thermal protection time extended to 170–200 seconds when the PCM melting points ranged from 50
  • C to 80
  • C but declined when the melting point surpassed 80
  • C.
Figure 3: Time for the human body skin surface to reach second-degree burn temperature (60
Original PDF Figure 3:
  • C) under (a) flashover and (b) hazardous conditions.

Effect of Phase Change Material Melting Points on Thermal Protection Behavior 65

The PCM showed better thermal protection performance when it was located close to the inside of firefighters’ turnout gear under high heat conditions, although the improvement in performance was not significant (Figure 4). This was because the PCM would melt faster and become a liquid state when it was located close to external heat sources, losing the phase change function early. When the PCM was close to the human body, it could slow down the melting process to extend the phase changing period and therefore the thermal protection time. In addition, the PCM segments could help double the thermal protection compared to conventional turnout gear without PCM (Figure 4).

Figure 4: Temperatures on skin surfaces at the locations of (a) Probe 1 (chest – representing human trunk) and (b) Probe 2 (arm – representing limb) under flashover condition. (PCM melting point at 60 ◦C). The figures show a distinct pattern of slow temperature rise with PCM compared to no PCM condition.
Original PDF Figure 4:

Limitations and Future Directions The human body in the simulation model was represented using various simple geometries, such as cylinders, cones, and ellipsoids (Figure 1), with dimensions based on the anthropometric data of firefighters. The primary objective of this study was to evaluate the thermal protection capabilities of PCM-integrated firefighters’ turnout gear with respect to different PCM melting points. Despite the use of a simplified model, the observed trends in the results for the human body remained valid. To achieve more accurate simulation outcomes, a detailed human body model with realistic body curvatures will be developed and studied. Additionally, experimental studies using a human manikin will be conducted to validate the numerical model and assess the thermal protection performance of PCM-integrated turnout gear. In the experimental study, the PCM segments will cover the entire turnout gear to demonstrate that the use of a few representative PCM segments in the simulation model could show similar thermal transport phenomena at the PCM-covered areas as the fully covered turnout gear (helps to reduce computational costs).

CONCLUSION

This computational study investigated the impact of phase change material (PCM) melting points on the thermal protection performance of PCM- integrated firefighters’ turnout gear. The findings indicated that the optimal melting temperature range for the best thermal insulation performance was between 50–80

  • C. The study also developed correlations that describe the relationship between the time required for the human skin surface to reach second-degree burn injury and the PCM melting points under both flashover and hazardous conditions. Additionally, it was observed that the thermal protection time could be extended by approximately 5 seconds under high heat conditions when the PCM segments were positioned closer to the inner surface of the turnout gear, as opposed to near the outer surface.

ACKNOWLEDGMENT

The authors would like to thank the CDC NIOSH Nanotechnology Research Center (NTRC) for its financial support of this research. The authors also thank Jay Tarley and Jeff Powell for their thoughtful review of this manuscript.

DISCLAIMER The findings and conclusions in this report are those of the authors and do not necessarily represent the official position of the National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention. Mention of any company or product does not constitute endorsement by the National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention.

REFERENCES

ASTM F1291 – 16 (2016). Standard Test Method for Measuring the Thermal Insulation of Clothing Using a Heated Manikin. ASTM F1930 – 18 (2018). Standard Test Method for Evaluation of Flame-Resistant

Clothing for Protection Against Fire Simulations Using an Instrumented Manikin. Brundrett, G., & Harmer, J. (2021). “The Role of Phase Change Materials in Protective Clothing.” Journal of Fire Safety Engineering, 35(2), 45–59. Balaji, P., et al. (2020). “Thermal Protective Performance of Firefighter Clothing.”

Journal of Occupational Safety and Health, 58(4), 212–227. Coletta, G. C., Arons, I. J., Ashley, L. E., Drennan, A. P. (1976). The Development of Criteria for Firefighters’ Gloves Volume II: Glove Criteria and Test Methods. National Institute for Occupational Safety and Health (NIOSH) Publication, No. 77-134-B. Fonseca, A., Mayor, T. S., Campos, J. B. L. M. (2018). Guidelines for the specification

of a PCM layer in firefighting protective clothing ensembles. Applied Thermal Engineering 133: 81–96. Fonseca, A., Neves, S. F., Campos, J. B. L. M. (2021). Thermal performance of a PCM firefighting suit considering transient periods of fire exposure, post-fire exposure and resting phases. Applied Thermal Engineering 182:115769.

Effect of Phase Change Material Melting Points on Thermal Protection Behavior 67

Globe GX-7 Firefighter JACKET Coat Size 36/32 Turnout Gear: https://www.the bigredguide.com/globe-gx-7-jacket-turnout-bunker-gear-technical-details.html. Harris, J. P., Yates, B., Batchelor, J., Garrington, P. J. (1982). The thermal

conductivity of Kevlar fibre-reinforced composites. Journal of Materials Science 17: 2925–2931. Hu, Y., Huang, D., Qi, Z., He, S., Yang, H., Zhang, H. (2013). Modeling thermal insulation of firefighting protective clothing embedded with phase change material. Heat Mass Transfer 49: 567–573. Incropera, F. P., DeWitt, D. P. (2002). Fundamentals of Heat and Mass Transfer.

5th edition. John Wiley & Sons. McCarthy, L. K. and di Marzo, M. (2012). The application of phase change material in fire fighter protective clothing. Fire Technology 48: 841–864. Mondal, S. (2008). Phase change materials for smart textiles - an overview, Applied

Thermal Engineering 28(11–12): 1536–1550. National Fire Protection Association. (2023). “Firefighter Injury Statistics.” NFPA 1971 (2018). Standard on Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting. PureTemp LLC: https://puretemp.com/. Su, Y., Li, R., Yang, J., Song, G., Li, J. (2020). Effect of compression on contact heat

transfer in thermal protective clothing under different moisture contents. Clothing and Textiles Research Journal 38: 19–31. Ventura, G., Martelli, V. (2009). Thermal conductivity of Kevlar 49 between 7 and 290 K. Cryogenics 49: 735–737. Xu, S. S., Pollard, J., Zhao, W. (2022). Modelling and analysing for thermal protection of firefighters’ glove by phase change material. Journal of Environmental and Occupational Health 12(2): 118–127. Xu, S. S., Pollard, J., Zhao, W. (2024). 3D Numerical simulation for thermal

protection of phase change material-integrated firefighters’ turnout gear. AHFE International, Human Dynamics and Product Evaluation and Quality 131: 1–9. Zhang, H., Liu, X., Song, G. & Yang, H. (2021). Effects of microencapsulated phase change materials on the thermal behaviour of multilayer thermal protective clothing. The Journal of The Textile Institute 112(6): 1004–1013.

Cover of the proceedings volume Human Dynamics, Product Evaluation and Quality

Explore the complete digital volume

Human Dynamics, Product Evaluation and Quality

Read this individual research paper free through the original publisher, or explore the full digital proceedings book.

ISBN 978-1-964867-48-9

Explore this ISBN in the AHFE Bookstore Listed in the July 2026 bookstore catalogue; search by ISBN to confirm current availability · Digital book purchase optional

Explore Related Research

Related research 8 matches

More papers from this volume

← Back to Research ExplorerBrowse the full library →